MeAndMyGang --- 18 years ago -

So, I go to turn onto Sycamore Springs, and it's blocked with what looks like a downed tree. Then I turn around, come in Shady Maple. I'm almost home, only to come across an accident at Shady Gardens and Bassingham! Geez, I hope the weekend gets better :) 

JustMeBeingMe --- 18 years ago -

There is a thread out there that someone heard a transformer explode...probably related.... 

ilovemykids1030 --- 18 years ago -

yeah i posted about the transformer, but i didnt hear anything about a tree!! lol full moon tonight?? 

MeAndMyGang --- 18 years ago -

I guess! It was just odd to see the cops at the tree, and then to come the other way home, and see cops at an accident! The accident on Bassingham actual involved an older lady and some kids, in I believe, a Camero. The kids went up into a yard. 

FourS --- 18 years ago -

tree fell on the transformer... we were out power for awhile 

Sue --- 18 years ago -

I don't understand why these transformers blow up. I've read of others, and it happened on the street behind us last year. They messed up a yard next to us to fix it, and our neighbor was livid at the mess leftback by the transformer. 

SuperFantastic --- 18 years ago -

In kingwood anytime we have rain then high winds a tree is bound to lean or fall on some electrical lines. Its the price you pay for living where there are trees. 

Sue --- 18 years ago -

The time this happened in Mills Branch, there was no wind. It was just a summer day. 

NowandThen --- 18 years ago -

The breakdown of a transformer can be due to many reasons such as Electric Fault, Thermal Fault, Internal Fault, Ageing Fault, Material Failure, Improper Loading, and Operating Environment etc. Older power transformers were originally designed to last 30-40 years. Their manufacturers did not anticipate the overwhelming increase in the electricity demand that we experience today. Surprisingly, after 50-60 years many of those transformers are still in use and they have to cope with increased loads. The insulating materials of older power transformers comprised cellulose and oil. When aging they absorb water which deteriorates the cellulose's insulating ability. In the case of heavy loads, water can also turn to steam which evolves in the form of bubbles. Degradation of insulating materials is one of the most important reasons for power transformer breakdowns. In some extreme cases the problem can cause a power transformer explosion. This explains the significant increase in power transformer explosions in the USA in the late 1990's. Power transformer explosions hit both companies and society, with costs amounting to billions of USD. Most large oil-filled transformers contain a Buchholz relay to detect abnormalities within the transformer, any abnormalities may trigger an alarm or send a trip signal. In the field of electric power distribution and transmission, a Buchholz relay, also called a gas relay or a sudden pressure relay, is a safety device mounted on some oil-filled power transformers and reactors, equipped with an external overhead oil reservoir called a conservator. The Buchholz Relay is used on conservator type oil preservation systems as a protective device sensitive to events which occurs during dielectric failure inside the equipment. When an electric arc or overheating develops inside the coils, gas is generated. The relay has two different detection modes. On a slow accumulation of gas, due perhaps to slight overload, gas accumulates in the top of the relay and forces the oil level down. A float operated switch in the relay is used to initiate an alarm signal. This same switch will also operate on low oil level, such as a slow oil leak. If an arc forms, gas accumulation is rapid, and oil flows rapidly into the conservator. This flow of oil operates a switch attached to a vane located in the path of the moving oil. This switch normally will operate a circuit breaker to shut down (isolate) the apparatus before the fault causes additional damage. Buchholz relays have a test port to allow accumulated gas to be withdrawn for testing. Flammable gas found in the relay indicates some internal fault such as overheating or arcing, whereas air found in the relay may only indicate low oil level or a leak. Buchholz relays have been applied to large power transformers at least since the 1940's. The relay was first developed by Max Buchholz in 1921. 